Key Facts

  • Frequency range from 5 kHz to 26.5 GHz
  • Port connectors configurable as 3.5 mm-compatible (m/f) or N-type (m/f)
  • Lightweight, rugged, portable

Economy calibration unit with a flexible configuration concept

R&S®ZN-ZE1xx calibration units combine the efficiency of automatic calibration procedures with a great price/performance ratio, and also offer the flexibility of configuring ports as needed. All models support 3.5 mm-compatible connectors, and the R&S®ZN-ZE104, R&S®ZN-ZE109 and R&S®ZN-ZE118 support N-type connectors as well. Once a connector type is chosen, each individual port can be further configured as male (m) or female (f)

Features & benefits

Lowest start frequency

Frequency ranges starting from 5 kHz

With a start frequency of 5 kHZ to 26.5 GHz, the R&S®ZN-ZE1xx perfectly supports the full frequency range of the R&S®ZND, R&S®ZNL, R&S®ZNLE and R&S®ZNH. The R&S®ZNA, R&S®ZNB and R&S®ZNBT are also supported.

Calibrate all port counts with each unit

Calibrate n-ports with a 2-port calibration unit

Calibrating more ports than offered by the R&S®ZN-ZE1xx is easy. A step-by-step guide helps users calibrate every port number with a two-port calibration unit, resulting in full n-port calibration.

Configurable test port types

Support for two connector system types

The ports on every R&S®ZN-ZE1xx model can be configured as 3.5 mm-compatible or N-type (not available for the R&S®ZN-ZE126). Each port can also be individually configured as male (m) or female (f).

Auto configuration and detection

Plug & play calibration

R&S®ZN-ZE1xx calibration units are automatically detected via the USB connection. All required data is transferred to the VNA. When starting calibration, connected test cables and port assignments can be found at the press of a button. Calibration requires minimal effort and time and maximum reliability.

Available models

Available models
Modelli
Type
Frequency range
Connector type
Number of ports
Description

R&S®ZN-ZE104

Order Number 1350.8040.04

Type
Calibration unit 50 Ohms
Frequency range
5 kHz to 4.5 GHz
Connector type
N (m/f) or 3.5mm-compatible (m/f)
Number of ports
2
Description
for R&S®ZNA, ZNB/T, ZND, ZNL, ZNLE, ZNH

R&S®ZN-ZE109

Order Number 1350.8040.09

Type
Calibration unit 50 Ohms
Frequency range
5 kHz to 9 GHz
Connector type
N (m/f) or 3.5mm-compatible (m/f)
Number of ports
2
Description
for R&S®ZNA, ZNB/T, ZND, ZNL, ZNLE, ZNH

R&S®ZN-ZE118

Order Number 1350.8040.18

Type
Calibration unit 50 Ohms
Frequency range
5 kHz to 18 GHz
Connector type
N (m/f) or 3.5mm-compatible (m/f)
Number of ports
2
Description
for R&S®ZNA, ZNB/T, ZND, ZNL, ZNLE, ZNH

R&S®ZN-ZE126

Order Number 1350.8040.26

Type
Calibration unit 50 Ohms
Frequency range
5 kHz to 26.5 GHz
Connector type
3.5mm-compatible (m/f)
Number of ports
2
Description
for R&S®ZNA, ZNB/T, ZND, ZNL, ZNLE, ZNH

Request information

Do you have questions or need additional information? Simply fill out this form and we will get right back to you.

Autorizzazione al marketing

La tua richiesta è stata ricevuta. Ti ricontatteremo a breve.
An error is occurred, please try it again later.
Informazioni generali e legali

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

You may use the electronic signature via DocuSign to submit your information to enroll with the Rohde & Schwarz Customer Delegated Administration program. DocuSign processes the information provided according to their . The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found

Termini e condizione del Concorso 10 anni di oscilloscopi Rohde & Schwarz

1. Il concorso a premi “10 anni di oscilloscopi Rohde & Schwarz” (di seguito il “Concorso”) è organizzato da Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Monaco di Baviera, Germania, Tel. +49 89 41 29 0 (di seguito “R&S).

2. Tutti i partecipanti possono registrarsi al concorso dal 1 gennaio 2020 al 31 dicembre 2020 comunicando il loro nome, azienda e indirizzo e-mail lavorativo.

3. La partecipazione al concorso è gratuita e non è legata all’acquisto di alcun bene o servizio.

4. Il concorso è aperto alle sole persone giuridiche e solo le persone giuridiche potranno vincere i premi. Non è ammessa la partecipazione delle persone fisiche col proprio nome e account, ma un rappresentante di una persona giuridica può compilare il modulo di partecipazione in nome e per conto della persona giuridica.

5. Il premio è costituito da un oscilloscopio R&S®RTB2000 tra i 10 messi in palio nel periodo dal 1 gennaio 2020 al 31 dicembre 2020:

Premio: 1 oscilloscopio digitale R&S®RTB2000

6. L’estrazione avrà luogo nella sede di Rohde & Schwarz di Muehldorstrasse 15, 81671 Monaco di Baviera. Il vincitore di un premio sarà informato via e-mail entro cinque (5) giorni lavorativi.

7. Il rappresentante autorizzato dalla persona giuridica dovrà informare Rohde & Schwarz della volontà di accettare il premio. In caso di mancata accettazione o di mancata risposta entro due (2) settimane, verrà estratto un nuovo vincitore. Se non si potrà identificare un vincitore entro quattro (4) settimane, il concorso avrà termine e il premio non verrà assegnato.

8. I dipendenti di R&S, i membri delle loro famiglie e le persone coinvolte nel processo di estrazione e i membri delle loro famiglie sono esclusi dalla partecipazione.

9. Non è previsto alcun equivalente in denaro o permuta del premio. I premi non son trasferibili. Tutte le eventuali tasse, imposte, tributi o altri addebiti dovuti nel paese di residenza saranno a carico del partecipante al concorso.

10. I dati personali verranno trattati al solo scopo dell’estrazione del premio e cancellati dopo quattro (4) settimane dall’estrazione, salvo diverso accordo.

11. Ogni partecipante che non rispetta quanto indicato in questi Termini & Condizioni potrà essere squalificato da R&S da questo Concorso. In tali casi, i premi potranno anche essere ritirati retrospettivamente. Qualora un premio venga ritirato retrospettivamente a causa del non rispetto di questi Termini & Condizioni, dovrà essere reso dal vincitore a sue spese, inviandolo all’indirizzo di R&S indicato al punto 1, dopodiché verrà determinato in nuovo vincitore.

12. I partecipanti non potranno richiedere i premi di questo concorso e non è ammesso alcun ricorso legale a questo proposito.

13. Il concorso ed ogni altro legame contrattuale di conseguenza derivante tra R&S e il rispettivo partecipante sarà regolato della legge tedesca, senza possibilità di ricorso in caso di conflitto tra legislazioni. Il tribunale di Monaco di Baviera avrà giurisdizione esclusiva in caso di ogni disputa diretta o indiretta derivante dalla partecipazione a questo Concorso.

* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.